Heron D130 Barcode Scanner Manual

DEFAULT VALUES

  1. Datalogic Heron D130 Barcode Scanner
USA keyboard, FIFO enabled, inter-character and inter-code delays disabled,
: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = ENTER, character replacement disabled.
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx

The Datalogic Heron D130 barcode scanner is an innovative, high performance solution designed to meet all the needs of small retail POS applications. When placed correctly in the stand, the Heron D130 automatically switches into hands-free mode, utilizing instinctive reading distance technology and the patented Datalogic Green Spot feature. Manual and automatic car.

May 12, 2003 - ASSISTANT PRODUCER 3.5. Talk-show Management Software for Telos third-generation Telephone. USER'S MANUAL. Advanced Multi-line Talkshow Screening Software Gets New Look, Added Power. Assistant Producer 3.5 works with both Telos Series 2101 and TWOx12. Jan 11, 2013 - The new version of Assistant Producer - v3.5.40 - is a no-cost upgrade which contains a long list of new features and software fixes that talk. Assistant producer job description.

timeout 5 sec., ack/nack disabled, FIFO enabled, serial trigger lock disabled.
: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = CR-LF, character replacement disabled.
USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock
unchanged, inter-character and inter-code delays disabled, control character
: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = ENTER, character replacement disable.
interpret mode, conversion to code 39 disabled, output level normal, idle level
normal, minimum output pulse 600 μs, overflow medium, inter-block delay disabled.
Enabled codes
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit control and transmission, variable length code; 4-99 characters

Datalogic Heron D130 Barcode Scanner

Standard Code 39
no check digit control, variable length code; 1-99 characters
Code 128
Disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI,
Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49, RSS Codes
Heron™ D130
Power Supply
RS232 interface
Maximum
Operating
Sleep mode/USB Suspend
Max. Scan Rate
Reading Indicators
Optical Features
CCD solid state (2048 pixels)
LED array
630 ~ 670 nm
0.31 mW
Class 1 EN 60825-1
2 ~ 27 cm (20 mils)
0.10 mm (4 mils)
min. 15%
0 °C to + 55 °C (+32° to +131 °F)
Storage Temperature
Humidity
IEC 68-2-32 Test ED
1.8 m (5.9 ft)
16 KV
IP30
Weight (without cable)
Cable Length
RESTORE DEFAULT
Ì$+$*oÎ
To change the defaults refer to the HHD II Software Configuration Manual, part
number 90ACC1877, or to the Configuration program, both downloadable from the
INTERFACE SELECTION
Select one of the interface codes according to your application.
USB-KBD
USB-KBD - ALT-mode
USB-COM *
USB-IBM-Hand Held
* When configuring USB-COM, the relevant files and drivers must be installed
from the USB Device Installation software, which can be downloaded from the
PEN EMULATION INTERFACE SELECTION
Barcode
Ì$+CP6$-BÎ
RS232 Standard
Nixdorf Mode A
Fujitsu
ICL Mode
WEDGE INTERFACE SELECTION
Ì$+CP500$-aÎ
Ì$+CP505$-ÈÎ
Ì$+CP508$-2Î
Ì$+CP507$-+Î
Many other interfaces are supported and can be selected from the HHD II
Software Configuration Manual available online at datalogic.com. Other supported
USB: USB-IBM-Table Top; USB-KBD-APPLE
WEDGE: IBM XT; IBM SURE1; IBM Terminal 3153; IBM Terminals 31xx, 32xx,
34xx, 37xx; Wyse Terminals ANSI – PC –ASCII – VT220 style Keyboards; Digital
KEYBOARD NATIONALITY
USB-KBD and Wedge users should select one of the following wedge keyboard
Belge
Deutsch
English
Español
Français
Italiano
Japanese
Svenskt
USA (Default)
DATA FORMAT TERMINATORS
For your convenience, some common Terminators are given below. For other
Header/Terminator selections, Data Format and Advanced Data Format
parameters, see the HHD II Software Configuration Manual.
Ì$+EA120D0A$-ÃÎ
Ì$+EA1183$-0Î
Ì$+EA1184$-8Î
Ì$+EA10$-dÎ
Read the TEST code below.
t
s
USING HERON™ SERIES READERS
Heron™ guns automatically scan barcodes at a distance. Simply aim and pull the
trigger. Code scanning is performed along the center of the light bar emitted from
the reading window. This bar must cover the entire code.
Successful scanning is obtained by tilting the scanner with respect to the barcode
to avoid direct reflections, which impair the reading performance, see the figure
Successful reading is signaled by an audible tone plus a good-read green spot.
By correctly inserting the reader into the stand, it is immediately ready to
automatically read any code present in its reading area without pressing the
trigger. Furthermore, a green aiming light is continuously emitted to facilitate the
positioning of the barcode to be read, see the figure above.
To guarantee single code reading, same code consecutive reading requires the
code to be removed from the reading area (no decoding) before the reader will
STAND INSTALLATION
B
The stand can be mounted by using self-tapping screws, double sided adhesive
A)
the
directly
the
using
B)
carefully clean the bottom surface of the stand and the table surface.
Remove the protective plastic from one side of the adhesive strips and stick
them on the stand bottom. Then, remove the plastic from the other side of
C)
carefully clean the bottom surface of the stand, remove the protective film
from the rubber feet and stick them in the corresponding housing on the
bottom surface. It is also possible to fix an optional metal plate.
Pair the reader to the stand paying attention to insert the handle into the stand clip
(see figure above). Correct insertion will be signaled by a beep; then, the reader
the
  • Quick Links:

Related Manuals for Datalogic Heron D130

  • Barcode Reader Datalogic Heron D110 Series Quick Reference
    For ibm 46xx terminals (22 pages)
  • Barcode Reader Datalogic DRAGON D131 Reference Manual
    (205 pages)
  • Barcode Reader Datalogic Heron D150 Quick Reference
    D150 eas readers (21 pages)
  • Barcode Reader Datalogic DRAGON D151 Quick Reference Manual
    Barcode reader (21 pages)
  • Barcode Reader Datalogic DS2100N Reference Manual
    Laser (119 pages)
  • Barcode Reader Datalogic DS1100 SH2347 Programming Manual
    Handheld laser bar code scanners (88 pages)
  • Barcode Reader Datalogic DS2400N Quick Reference Manual
    Datalogic laser scanner quick reference guide (20 pages)
  • Barcode Reader Datalogic DS6300 Reference Manual
    (62 pages)

Related Content for Datalogic Heron D130

  • FireScan D131 Default Values
  • DS6500 Parameter Default Values
  • DX6400 Parameter Default Values
  • DS6400 Parameter Default Values
  • DS6300 Parameter Default Values
  • DS6300 Parameter Default Values
  • Gryphon Default Values
  • DX8200A Parameter Default Values